BER performance comparison of EEG healthcare system using 8-pixel, 16-pixel OLED screen, and DSLR camera

Geetika Aggarwal, Xuewu Dai, Reza Saatchi, Richard Binns

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Electroencephalography (EEG) is predominantly used in healthcare to analyze the brain activity through sensors or electrodes placed on scalp. The conventional EEG systems based on radio frequency (RF) technology used in healthcare are tedious, involve long preparation times, and suffer from electromagnetic interference (EMI). Furthermore, in hospitals, specifically intensive care units (ICUs), EMI from RF devices might cause an adverse effect on both patient’s health and medical devices. Therefore, in context to the flaws of RF technology in healthcare in addition to frequency crunch, a subdivision of optical wireless communication, known as VLC, is preferred. The captivating dual functioning of communication and lightning of VLC deploying LEDs in addition to low cost, no eavesdropping, and EMI free has enhanced the scope of VLC in numerous applications such as indoor localization, underwater communications, vehicle-to-vehicle communications, and many more. VLC systems use either photodiode as a receiver or camera. The use of camera in VLC systems as receiver reduces the infrastructure tariff substantially because of no requirement of additional amplifiers, filters, etc., unlike VLC systems, where PD is the receiver. In that viewpoint, this chapter experimentally demonstrates the BER (bit-error-rate) performance comparison of novel EEG healthcare system using 8-pixel and 16-pixel organic light emitting diode (OLED) screen and DSLR camera as transmitter and receiver, respectively. The lab tests were conducted at 30 fps with both 8-pixel and 16-pixel OLED screen. The proposed system achievable bit rate was 2.8 kbps and the error-free transmission up to 1.75 m and 2.25 m with 8-pixel and 16-pixel OLED screen, respectively. The experimental results showed that there is a trade-off between the pixel size and BER, as with smaller pixel size, bits transmitted per frame is enhanced in comparison to larger pixel size; however, BER significantly increases for smaller pixel size when compared the BER results of 8 and 16 pixel, respectively. Due to system on chip solution, low cost, low power design, and free from EMI, the proposed system prototype has the potential to be deployed in 5G in RF sensitive areas such as hospitals and future technology for remote or wireless brain monitoring among patients for EEG applications in brain–computer interface.

Original languageEnglish
Title of host publicationSmart Biosensors in Medical Care
PublisherElsevier Masson
Pages107-123
Number of pages17
ISBN (Electronic)9780128207819
ISBN (Print)9780128209363
DOIs
Publication statusPublished - 1 Jan 2020
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2020 Elsevier Inc. All rights reserved.

Fingerprint

Dive into the research topics of 'BER performance comparison of EEG healthcare system using 8-pixel, 16-pixel OLED screen, and DSLR camera'. Together they form a unique fingerprint.

Cite this