Abstract
The performance of a bench scale ‘anaerobic fixed-film down-flow bioreactor’ with glass bead as a packing material for treatment of high strength wastewater (spent wash) in terms of percent Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD) removal at various temperatures has been studied. The reactor is operated at temperatures ranging from 35oC to 51oC for hydraulic retention time (HRT) of 15 days. For this hydraulic retention time, experimental results show that COD removal is 60-64.8 % and BOD removal is 65.3 – 70%. The maximum percent COD and BOD removal is observed at 41oC.
Original language | Undefined |
---|---|
Pages (from-to) | 587-591 |
Journal | Journal of the Chemical Society of Pakistan |
Volume | 33 |
Issue number | 4 |
Publication status | Published - 8 Aug 2011 |